บทคัดย่องานวิจัย

Analysis of total aerobic viable counts in samples of raw meat using fluorescence-based probe and oxygen consumption assay

Fiach O’Mahony, Rebecca A. Green, Chris Baylis, Richard Fernandes and Dmitri B. Papkovsky

Food Control, Volume 20, Issue 2, February 2009, Pages 129-135

2009

บทคัดย่อ

Analysis of total aerobic viable counts in samples of raw meat using fluorescence-based probe and oxygen consumption assay

A simple test for determining total aerobic viable counts in raw meat is presented. Homogenates of meat samples are prepared in full PBW medium, dispensed in the wells of 96-well plate together with the oxygen-sensing probe, Redlight, covered with oil and monitored o­n a fluorescent reader at 30 °C. The probe produces characteristic sigmoidal profiles of fluorescence reflecting depletion of sample dissolved oxygen, with o­nset time indicating the initial microbial load. The test provides rapid and accurate results (1 and 12 h for contamination levels of 108 and 103 cfu/g, respectively) and correlates well with the ISO:4833:2003 method (r = 0.86), which make it useful as alternative to conventional culture methods for the quick, high throughput determination of TVC (30 °C) in meat samples.